Mfg Part Number: EAS81055-1 | Alternate P/N: EAS810551 | NSN : 5925-01-551-1265 |
NIIN : 015511265 | CAGE Code : 90598 | Manufacturer: Engineered Air Systems Inc |
Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers |
Thank you for your continued interest in the parts associated with the NSN 5925-01-551-1265, those of which are readily available for purchase on Automatize Electronics. The Circuit Breaker item associated with the part number EAS81055-1, by Engineered Air Systems Inc, is currently available on our database; thus, if you wish to begin the part number EAS81055-1 procurement process, we ask that you please fill out and submit an Instant RFQ form detailing your requirements on parts needed. This includes desired quantities, target prices, expected shipping time frames, and more, as applicable. Upon receival, our representatives will harness your provided information and formulate a solution which satisfies your operational needs in just 15 minutes or less.
With our global supply chain stretching across the United States, Canada, and the United Kingdom, Automatize Electronics can provide expedited shipping on select NSN products with the CAGE Code 90598, strategically assisting entities facing an Aircraft on Ground (AOG) situation or other unique time constraint. Operating with a strict NO CHINA SOURCING pledge, all items are shipped alongside their manufacturer trace documentation or qualifying certifications, ensuring that customers feel confident in every purchase made. With cost savings and rapid lead times bolstering every order, experience all of what Automatize Electronics has to offer on products with the NSN 5925-01-551-1265 by submitting your RFQ for parts by Engineered Air Systems Inc. submit a quote for the part number EAS81055-1, today!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-551-1265 Item Description: Circuit Breaker | 5925 | 015511265 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Eas81055-1 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 5.312 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC ALL LOCATIONS AND 20.0 AMPERES DC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 15000.0 AC ALL LOCATIONS AND 1000.0 DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 480.0 AC ALL LOCATIONS AND 250.0 DC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.375 INCHES NOMINAL |
CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 1 ROTARY |
AJEC | Boss Height | 0.250 INCHES NOMINAL |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
ADAT | Body Width | 4.125 INCHES NOMINAL |
CPRX | Actuator Position Designation | AT POLE TWO |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
TTQY | Terminal Type And Quantity | 6 COMPRESSION |
ADAQ | Body Length | 6.219 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 5.312 INCHES NOMINAL |
ADAU | Body Height | 3.781 INCHES NOMINAL |
FEAT | Special Features | NOT AVAILABLE IN NEW CONDITION. ONLY RECONDITIONED ARE AVAILABLE |
PKDW | Packaged Unit Weight | 7.000 POUNDS |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.375 INCHES NOMINAL |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AGAV | End Item Identification | MINUTEMAN |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 11.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 35.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AEBV | Unthreaded Mounting Hole Diameter | 0.225 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
MRC | Decoded Requirement | Clear Text Reply |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote